Drugloo Evolution

drugloo_evolution

This Drugloo is semi-automatic. All aspects of the recovery procedure are controlled from the front of the suitable duration and sequence of washing and retrieval of the packages. The operator does not have to manually manipulate any of the recovered substances. The interior of the recovery chamber is clearly visible at all times to maintain continuity of evidence. Packages and faeces are automatically transferred from the WC bowl into the washing/recovery chamber, and can be gently tumbled whilst being sprayed with water into which has been injected the correct amount of Anti-Microbial Concentrate via the automatic dosing unit contained within the equipment.
The equipment compromises five pre-fabricated parts, which are easily bolted together on site:-

The complete equipment is manufactured from high grade stainless steel unless otherwise stated and built sturdily enough to withstand the abuse likely to be encountered in the environment in which it is to be installed.

Stepped base unit

This is a set of steps, which fit onto the front of the WC unit to provide access to the WC. Straight or 90o available. (Please specify when ordering).

WC Unit

This is the main body of the equipment compromising WC bowl, recovery chamber and automatic dosing unit. This is fully factory plumbed with external connections for water inlet, waste outlet and mains electricity.

Side Screen

Manufactured from Stainless Steel with a 9mm thick laminated glass viewing panel.

Rear Screen

Manufactured from Stainless Steel with Stainless Steelinfill panel

MAINS SERVICE REQUIREMENT

Mains Water

Clean, with a minimum pressure of 4 bar (approx 56 psi) and a volume of 20 litres/min.

Electricity

Mains electrical supply 110v or 240v (specify when ordering ) This supply must be fitted with a safety protection to the system and must be installed and tested by a qualified person. This supply should be in the form of a switched and fixed spur, into which the 12V power unit, supplied to operate the Drugloo, is connected.

Soil

The waste outlet from this equipment is via a 2″ BSP socket and should be discharged into the building soil system.

NB: Minimum headroom for both options is 2.6m